PRESSURIZATION
SERVICE AIR (23 psi)
De-Ice Boots
Press Outflow Valve
Cabin Door Seals
Throttle Detents
Pre-Cooler
In Flight 475°C (±25)
Ground 405°C
Bleed Air O'Heat Light 560°C
Cabin Air
Dive Solenoid
Hydraulic Brake Reservoir
35°F Temp Control
If the temp exiting the water separator falls below 35°F, the TCV modulates open to mix hot air with the cold air to prevent water from freezing the water separator. (The water is sprayed into the secondary heat exchanger)
EMER PRESS Illuminates:
Selected Manually
ACM Overheat
Cabin Alt Exceeds 14,500'
NORM PRESS CB Out
* EMER PRESS is not available on the ground.
Anticipater Valve - 31,000'
Cabin Heat, if manually adjusted above 31,000' may freeze and auto mode will not function properly.
Pressurization
29.92" Mercury/1013.5 mb
14.7 psi @ sea level
7.35 psi @ 18,000'
Max Capability
6800' Cabin Altitude @ 45,000'
Maintain Cabin Altitude @ Sea Level up to 26,000'
Adjust Cabin Altitude to Set Limit by 1500' above Landing Field Elevation
Starts to adjust cabin pressure for arrival at FL250 during descent
Lowest Setting in Controller is FL110
(Also the display when powered on)