ELECTRICAL SYSTEM

Battery: 20 Cell,
44 ampere hour nickel cadmium
25 VDC Power

10 Minutes
Power to ALL Buses

30 Minutes
Hot Batt/Emer Bus

Starter Generator: 30 VDC, 300 amperes
(regulated to 28.5 VDC)

Generator Load - Shared Equally
(10% of total load)

BATTERY BUS:
  Tailcone Baggage Light
  Tailcone Access Light
  Cabin Entrance Lights
  Emer Exit Signs
  APU Oil Light (preflight access)
  Lav Service Overfill Light

X-FEED BUS:
  Ignition in NORM/ON
  Taxi Lights
  Wemac Fan
  Fwd/Aft AC Evap Fans

EMERGENCY BUS:
  Comm 1
  NAV 1
  Standby Radio Control
  Pilot's/Copilot's Audio Panel
  AHRS 2 (airspeed/altitude)
  Standby HSI
  N1 indicators
  Standby Pitot Heat
  Cockpit Flood & Glareshield Lights
  Flap Control
  Gear Control
  Stabilizer Control
  Gear Warning
  Hydraulic Control Valve
  Ignition (SEC Position)

EMER LIGHTS BATTERY PACK:
  Emergency Lights
  Located on Pilot's Side Panel and
  Aft Closet

Illumination of EMER Lights:
  Loss of Main DC Power
  5 "G" Impact Switch
  Emer Light Switch - ON

EMER LIGHTS:
  Every 3rd Bulb of the LH   
  Fwd and RH Aft Isle  Lights
  Cabin Exit Signs (6)
  Reading Lights (4)
  Over Wing Exit Lights

Battery Pack
Left Nose Compartment
Good for max. 30 minutes
  Meggit
  Back Lighting for N1
  Gauge and Standby HSI

Battery Pack
Right Nose Compartment
Backup Power for AHRS 2
Good for max. 30 minutes

BATTERY BUS:
Tailcone Baggage Lights
Tailcone Access Lights
Cabin Entry Lights
Voltmeter
(Batt Switch ON/EMER only)
Emer Bus (Batt Switch in EMER Only)

GCU:
   Regulates
   Parallels
(within 10%) (30 amps)
   Protects
      * Power Relay
   Undervoltage
   Reverse Current
      * Field Relay
   Overvoltage
   Feeder Fault
   Fire Switch

BATTERY LIMITS
3 Engine Starts per Hour

Batt Start
1 Battery Debit

Gen Assisted
1/3 Batt Debit

Starting APU
1/3 Batt Debit

GPU Start
0 Batt Debit

Air Start
1 Batt Debit

STARTER LIMITS
Battery:
3 starts/30 minutes 90 sec. cooling period

Batt Limit: 3 Starts / Hour
                APU 9 Starts/Hour

GPU:
  800 - 1000 amperes
  28 VDC
  On/Running plugged in
  BATT Switch - ON
  GEN Switches - OFF

During Start - Disconnect Generators so they
don't participate in the start.

BATTERY OVERTEMP LIGHT:
  Flashes - 145° C.
>160 
  Flashes - 160° C.

GCU regulates the 30V DC generator to 28.5 VDC

GCU parallel the generators to share the load;
the generators must be within 0.3 volts and
10% of system load.

Gen Load Limit Flight:
300 Amps

Ground:
200 amps per Gen. transient up to 250 amps
for 4 minutes.